Relative Position Configuration (0x0D,0x55)
Description |
Configure the reference location for filter relative positioning outputs |
||||||||||
Notes | |||||||||||
Parameter Name | Data Type | Description | |||||||||
Field Length | u8 | 5 | |||||||||
Descriptor | u8 | 0x55 | |||||||||
Function Selector | u8 |
This command supports the following MIP function selectors:Write Read Save Load Default
[WRSLD]
|
|||||||||
Source | u8 | 0 - auto (RTK base station), 1 - manual | |||||||||
Reference Frame Selector | u8 enum |
ECEF or LLH
|
|||||||||
Reference Coordinates | vector3d | reference coordinates, units determined by source selection | |||||||||
Response Data | Data Type | Description | |||||||||
Response Length | u8 | 4 | |||||||||
Response Descriptor | u8 | 0xD5 | |||||||||
Source | u8 | 0 - auto (RTK base station), 1 - manual | |||||||||
Reference Frame Selector | u8 enum |
ECEF or LLH
|
|||||||||
Reference Coordinates | vector3d | reference coordinates, units determined by source selection |