Adaptive Filter Control (0x0D,0x53)

Description

Configures the basic setup for auto-adaptive filtering. See product manual for a detailed description of this feature.

Notes
Parameter Name Data Type Description
Field Length u8 6
Descriptor u8 0x53
Function Selector u8 This command supports the following MIP function selectors:
Write Read Save Load Default [WRSLD]
Level u8 Auto-adaptive operating level:
0=Off,
1=Conservative,
2=Moderate (default),
3=Aggressive.
Time Limit u16 Maximum duration of measurement rejection before entering recovery mode (ms)
Ack/Nack Reply See standard MIP ack/nack reply format.
Response Data Data Type Description
Response Length u8 5
Response Descriptor u8 0xD3
Level u8 Auto-adaptive operating level:
0=Off,
1=Conservative,
2=Moderate (default),
3=Aggressive.
Time Limit u16 Maximum duration of measurement rejection before entering recovery mode (ms)