Adaptive Filter Control (0x0D,0x53)
Description |
Configures the basic setup for auto-adaptive filtering. See product manual for a detailed description of this feature. |
|
Notes | ||
Parameter Name | Data Type | Description |
Field Length | u8 | 6 |
Descriptor | u8 | 0x53 |
Function Selector | u8 |
This command supports the following MIP function selectors:Write Read Save Load Default
[WRSLD]
|
Level | u8 | Auto-adaptive operating level: 0=Off, 1=Conservative, 2=Moderate (default), 3=Aggressive. |
Time Limit | u16 | Maximum duration of measurement rejection before entering recovery mode (ms) |
Response Data | Data Type | Description |
Response Length | u8 | 5 |
Response Descriptor | u8 | 0xD3 |
Level | u8 | Auto-adaptive operating level: 0=Off, 1=Conservative, 2=Moderate (default), 3=Aggressive. |
Time Limit | u16 | Maximum duration of measurement rejection before entering recovery mode (ms) |