Zero Angular Rate Update Control (0x0D,0x20)
| Description | Zero Angular Rate Update | |
| Notes | The ZUPT is triggered when the scalar magnitude of the angular rate vector is equal-to or less than the threshold value. The device will NACK threshold values that are less than zero (i.e.negative.) | |
| Parameter Name | Data Type | Description | 
| Field Length | u8 | 8 | 
| Descriptor | u8 | 0x20 | 
| Function Selector | u8 | This command supports the following MIP function selectors: Write Read Save Load Default 
                            [WRSLD]
                         | 
| Enable | u8 | 0 - Disable, 1 - Enable | 
| Threshold | float | [radians/second] | 
| Response Data | Data Type | Description | 
| Response Length | u8 | 7 | 
| Response Descriptor | u8 | 0x8E | 
| Enable | u8 | 0 - Disable, 1 - Enable | 
| Threshold | float | [radians/second] |