Factory Streaming (0x0C,0x10)

Description

Configures the device for recording data for technical support.

Notes

This command will configure all available data streams to predefined formats designed to be used with technical support.

Parameter Name Data Type Description
Field Length u8 4
Descriptor u8 0x10
Action u8 enum
Name Value Description
OVERWRITE 0 Replaces the message format(s), removing any existing descriptors.
MERGE 1 Merges support descriptors into existing format(s). May reorder descriptors.
ADD 2 Adds descriptors to the current message format(s) without changing existing descriptors. May result in duplicates.
Reserved u8 Reserved. Set to 0x00.
Ack/Nack Reply See standard MIP ack/nack reply format.